1100 Juanita St , Austin, TX 78704-5351 is a single-family home listed for-sale at $2,649,000. If you use our referring links, it costs you nothing extra. It should be 110V or 220V AC. The tripper will not move. I have an Intermatic t104. If its not, it wont work properly. Reference Manual & Buyer's Guide Another Brick in the It is generally not recommended to reuse a critical fastener like the rear spinal nut on your 2000 Ford Focus. You will first need to adjust the time on the timer first. I noticed that the on flipper was a little bit bent so I replaced it with new one. Articles and resources for swimming pool owners and DIYers. I looked to see if the gears on the timer are running. The T104RD89 timer will work with a swimming pool motor as long as the motor is 240 VAC and is under 5 HP which is what this timer is rated for. Like # 8 09-16-07, 03:09 PM nap New Member Join Date: May 2006 Location: north Posts: 4,162 any suggestions about how i might avoid another situation like the above would be appreciated. Gas pool heaters are one of the best additions to a pool, but they are the most high-maintenance piece of equipment on, 22,000 pool parts in stock! To do this, pull the yellow-faced time dial (clockface) toward you. Replaced timer motor on a T10404R Now time is running fast about 2 hrs. "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
With power off, you could also check the tightness of the on/off switch, it may be missing the tension spring also, check that its there. Thanks for the suggestions.. Is it Necessary? I went to my houses main panel breaker and Flipped that breaker which leads to the pool panel breaker and replaced that breaker which goes straight to the timer. sometimes Im forgetful lol what are your thoughts? Tighten them with a wrench. Align the bar with the current time and push it back into place. Hello have a question some what related. Thank you, I dont know about the box, was just told the mechanical timer a T104 is needed. I had a thunderstorm last night and my power went off for like 3 hours. Thank you. Look for any disconnected or damaged wires leading to the motor on the rear of the clock. Also be sure that the ON dog is not actually an OFF dog, and that it is tightly secured to the dial edge and pushed all the way onto the dial, and straight. "dateModified": "1/10/2020",
You can turn that yellow dial by hand CW to see if the trippers hit the off and on switch and to set the time on it. Generally, plug-in-outlet timer has gone bad, then it cannot be fixed. Also I have rotated the dial several times to trip on and off hoping that it lubricates the problem lever and dusts off the coil well. Is it keeping time normally? I have changed the dog tripper and that does not take care of - Answered by a verified Electrician . I looked through the visual motor check and the gear still moving fine. Pool Timer Not Turning ON or OFF!! If your 120V wires are properly colored, the White wire connects to terminal A, and the Black wire connects to terminal 1. Hi Tyler, maybe the dial is now pushed forward, far enough to where the trippers do not contact the switch? Power surges could be to blame. Is this broken? You could spray some light lubricant like WD-40 or 3-in-1 oil onto the gears both for the motor and behind the dial. the ground wire? You can have as many ON an OFF trippes as you want. To set it, you just move the on/off "trippers" where you want them. I have a inground pool with T10003RT4 control panel. I turned the breaker off and back on and still not working. Are the gears engaged, in the center, behind the dial? Basically youre eliminating possibilities until you find the cause. It randomly loses the time that it is set to. So, the off dog just slips across the switch and doesnt allow the switch to turn off the motor. Morgan Burley Im ready to send my back for a replacement. So what you will need to do next is to troubleshoot your Intermatic timer with a few steps. Using Your Timer to Optimize Your Pool Pump Download Article 1 Check the chemical balance of your pool. There is a second switch between the breaker and the timer. How to fix a Pool Pump Timer - Easy replacement using the Intermatic T104 Darren Does Everything Pool Timer Not Turning ON or OFF!! I had the exact same thing happen recently. If youre not sure which is the best timer for your pool to get, we have a full blogpost for which Intermatic timer you should get for your pool. Pools are not cheap! I have the PF1202T timer on my pool. How can it keep time if lever is in off position (manual lever). Almost like it doesnt have the strength to click the timer on or off. Its hard to give a fixed order for the steps you should take as it depends on what you found in the previous steps. Pool Timer Clock Parts and Trippers Welcome to Pool Spa Outpost! Other causes include rusted springs, insect infestation and loose timer dogs. The clock is powered from the Line 1 terminal correct? not sure what is the problem. VIDEO TOUR. For additional tripper pairs on CLOCK-DIALorder 156T1978A. When I turned it back on now the pool clock goes backwards. Your email address will not be published. "height": "219",
AJH Trade Group Australia Pool Equipment | Pool Lifestyle | Pool Heating | Pool Maintenance | Pool Problems, what to do when the pump circuit breaker continually trips. If all looks well, and the gears are still not turning, you may need to replace the mechanism. Back when I was a young technician I was taught to always look for the easy things and use all my senses. We cover T101, T103 and T104 models of mechanical pool timers. The timer not working is for the pump. If the motor gears are not turning, check the wire tightness (Breaker off first), and depress the tab at top to inspect the rear of the mechanism, to see if anything looks funny back there. What do you suggest to do to get the cover up and the pillows back into position. I had to replace my 2 year old intermatic timer motor this season as gears werent turning. (usually not). We had a storm last week and the yard flooded my pool so I went and switched the pool off at the breaker so it would not come on with the tabs until we were able to handle the pool. If you loosen the hold down screw to much it could separate from the timer pin. The freeze protection on your clock, the probe may be bad or malfunctioning, and may be turning off the pump. Things are working fine and all of a sudden the pool pump did not start in the morning. Sometimes the on/off switch on Intermatic and other mechanical timers can get tight. I reset the breaker and tested the GCFI and I have 240V going in and out of the timer still but my pump isnt moving. Hello, I notice today that my pump wasnt running so I opened the pool breaker panel where the timer is and noticed the breaker was tripped. It also provides a selectable voltage switch that enables you to choose between 120 and 240V, depending on what voltage you use and also has a battery backup option. Analog timers are the simplest type of pool pump timer and are easy to use (and the cheapest). Some white lithium grease on the switch can help in some cases. It has 4 screws below the dial labeled from left to right: LINE 1, LINE 2, LOAD 1, LOAD 2. 240V out of the timeclock (Load/Load terminals) and nothing on the motor terminal board? Clock wont move, gear dont move at all. Switch the breaker off at the power board. This will disengage the dial from the . Start with the easy checks. Some of the replacement motors make it past quality control with the incorrect gear setup. Does the tripper work on other areas of the clock, like near the off tripper? I found a diagram showing neutral to A, line 1 to terminal 1 and line 2 to terminal 3. Sometimes we suspect the timer is the issue but it turns out its really the pump or the wiring between the pump and the timer. when the lever is in the off position the gears stop turningis this unit wired incorrectly, Natural goes to A The time does not advance after resetting. Tork pool timer dial, spins freely, not keeping Timer is not 100% identified. Sometimes its way quick just to replace it rather than spend hours troubleshooting. Or fold the cover to one side if needed. This site is owned and operated by AJH Trade Group. I have a Model T104P and have a new green on tripper attached. You may notice that the time pointer is loose or is moving around too much.If you find your pointer is loose, simply tighten the screw that holds the timer in place so that it doesnt wiggle around. Related Reading: Should You Get a Pool Pump Timer? What is the problem? They are: Heres how to troubleshoot a mechanical pool timer step-by-step: It goes without saying that you should be qualified if you intend on working with live power. Make sure the middle time pointer is tight. I have a white, red, and black wire coming from the power source. Lately, the timer mechanism on my old T104R does not move. Now, Im going to order some additional timer clips. charging for timer($150.00) and filter cartridge replacement ($90.00) and a gasket($25.00)called bc of a hose leak, assume that is the gasket but then told that the other 2 parts are needed. I manually turn it on timer is running, it will trip pump OFF. Hi Joe, could be time, for new timer. If you dont have the voltage here you have an issue with either the wiring or the breaker. Richard, pull the mechanism out of the box by releasing the clip at the top and inspect the copper strips and pads on the rear. Now ever sense I did that last week my timer wont shut off or turn on my pool pump. If moving that is difficult, you could just avoid using the switch and turn the pump off with the timeclock instead, always keeping the switch on, and maybe taping the switch, to remind people not to use the switch. Any advice on how to fix. I believe its the manual on/off switch that is the problem. ft. 975 Telegraph Rd #103, Santa Paula, CA 93060 $409,000 MLS# V1-15365 Hillview Estates, where you own the land, and this one has a big lot, over 4,100. everything seems to be working correctly, but i can not turn the pump on or off by tripping the mechanism. Thanks. Jump to the troubleshooting steps below to fix the issue. Pop-in a new timer mechanism, and replace the wires to the previous configuration. Look into the visual motor check window, near the top of the timer mechanism. No luck. Give it a little squirt of WD-40 or similar lubricant. March 16, 2022 by WildRiverCountry. Tracing the power it goes from breaker to control panel, and then to the time clock, then to the pump. If the power has gone out, your just opening your swimming pool for the season or some third reason, you may need to adjust the time on your Intermatic swimming pool timer. I replaced T104 timer it runs and shuts off with no issue but once off the timer does not move or turn back on. "headline": "Intermatic Pool Timer Troubleshooting",
The tabs on the back of the timer may have fused together, or the tabs on the stationary switch at the rear of the motor, from a power surge. Hello. "
Once you do some you will want to re-tighten the hold down screw on the timer pin so it stays in place. Check that the motor gears are still moving also, when it gets to the switch and the dial stops moving. $115 Providence distortion MIJ - $120 All working perfectly Should be clear in photos which include boxes, others will be bubble wrapped and . Hi Alfred, I would guess that either the time dial is bent, or that the larger gear behind the dial is missing a tooth, at 10 pm, or has a bit of grit stuck in the gear at that point. We recommend these Intermatic timers for most pools:Intermatic T101 Intermatic T103Intermatic T104Intermatic T103. But eventually, like all equipment, intermatic clocks wear out and need to be replaced or repaired. If the trippers are set for on and off pump function and nothing is working, reset the time and trippers. Watch these tips and tricks before replacing it. AJH Trade Group is a participant in the Amazon Services LLC Associates Program. #9. I have replaced my pool timer 3 times in the last week and they will work for a day then quit working any idea what the problem could be? It started lagging again a week or so ago. TO SET TIME-OF-DAY:Pull CLOCK-DIALoutward. Two days ago after my pool pump shut off automatically I decided to turn it back on because the pool was still dirty. My Intermatic Pool Timer still works like normal but, when it gets to the time set to turn pump on or off it doesnt. I have a intermatic T101 and the clock doesnt move I replaced the old one due to burned out motor . Also, once it reaches the tripper, the gears in the window no longer move. Ill revise the scathing review I gave the unit on Amazon ratings to reflect the change. PF1202T Freeze Protection Control Parts - INYOPools.com Home Pool Parts Time Clock & Control Parts PF1202T Freeze Protection Control Free Shipping on all Orders over $49! Electrical Monke Aug 25, 2021 #22 It's broken. Resolved! The clock not turning on your Intermatic pool timer is a common issue. If youve followed this guide or arent confident in diagnosing the issue yourself, seek a qualified pool technician or electrician. I didnt check the connections because it seemed like an ordeal to take the timer apart to get to the wiring and I didnt want to make matters worse. Then turn the breaker, that the time clock is connected to, off and back on again. Next step would be to inspect the wires going from timer to pump motor, or test them for continuity. by pool co. , so wondered about the cost. Step 1 - Check that Timer is Functional Locate the two timer pins on your timer. Check out our online selection of new Intermatic timer clocks at InTheSwim.com! There is power; gears are moving. Replace them if they appear to be bent. First, you need to set the time, which is good to know in case of a power outage, or daylight savings adjustments. Hi Derrick, first try to reposition the timer tripper, making sure it is all the way on the dial. Hi, new timer out of the box, 200V. Have you any suggestions at to why I am experiencing this problem? Any ideas why its doing that? It stays on until I turn off the circuit breaker. Terminals 2 and 4 are used for wires going to the load (pump). on two occasions the plug from the pump almost melted and the second time the pool pump plug had to be replaced and i discontinued using the timer and disposed of it. document.getElementById( "ak_js_1" ).setAttribute( "value", ( new Date() ).getTime() ); Professional plumber and home repairs expert, How To Remove Broken Hayward Super Pump Drain Plugs. On occasion the two points that are used for setting the ON and OFF times for the pool pump get damaged or loosen. This product is certified by Amazon to work with Alexa. With the breakers turned off, remove the mechanism from the box. It just stays at that time. Then remove the mechanism by pressing the clip at the top of the timer box. The power should run from the breaker, to the timer, to the pump. "@context": "https://schema.org/",
Commonly, many pool owners will think there pool timer is broken and not working when all they had to to is turn the circuit breaker to the on position. my pool timer the does not turn itself on only shuts off I put new trips in but still not working I dont see any ant build up inside there or anything could it just be time to replace the old girl because thats what Im thinking. Hi there, How do you know if your pool timer is bad? Confused. Also be sure that the front dial is engaged with the gear located behind the dial. No high loop or air gap in the old under-the-sink dishwasher drain, Consider radiant underfloor heating system, Several Important Steps Homeowners Can Take To Protect Their Furnace, 4 Kinds Of Chemical Drain Cleaners That Clear Out Drains and Their Hidden Dangers. 4 Beds. Can the pool timer be placed inside the garage to protect it from the harsh weather. Then after a bit, the pump restarts. What happened? "name": "Davy Merino",
After a few days its off by 6 or 7 hrs but still turns on and off fine any suggestions? Since you have another switch in between the breaker and clock, the breaker will lose power when the switch is turned off. Thanks. When the power goes out, the timer stops. If you look closely (with a flashlight and your glasses! I have three outlets going out one to the pump , one for the salt system and one for the GFCI outlet. Perhaps bad wiring or a bad breaker is to blame. If you need to set the time, you will need to take two fingers and slightly pull the wheel towards you and away from the back of the timer box. Hi Matthew T104 can only turn one pump on and off. If dial is rotating correctly, but water heater never turns on-off, then trippers might be bad. Timer not tripping pump on. Reset the clock to the correct time. Open following links to identify timer and then add a comment. You can always call us at 815-675-7000 M-F 8am-4:30pm CST and speak with a live technician. I would suggest calling Intermatic and suggesting that idea and a free replacement? At some time the timer was disconnected and the pump wired direct to the breakers. To use an analog timer, you simply need to set when you want the timer to be on and off using trippers. Second thing to check is the dial bent or warped, in that area where the on tripper is? You off course will want to adjust one time pin at a time. Filter pump is ON at all timer Timer contacts welded Replace timer 5 .