1.11 Energy and CALGreen Documentation: Provide California Energy Code prescriptive or performance method compliance documentation, registered by an approved agency as applicable. 18.12 Sloped Glazing and Skylights. 1.9 Details: Submit foundation, floor and roof details, beam connections, special framing and flashing details as necessary for construction. And of course do not build in that area. (CEC 210.52F), 6.3 Kitchens and dining areas must have a minimum of two 20 ampere circuits. Per Table R905.1.1(1), ASTM D226 Well & Septic, Use, or Zoning).More Information:When Is a Building Permit Not Required? Attachment methods vary depending on the style of stairs but this is a very common and reliable technique. 1st deck RAILINGS WHAT YOU NEED TO KNOW 36 "minimum height when surface is 30" + above grade The official information and resource site for rebuilding efforts related to major wildfires in unincorporated Sonoma County. (R302.3), Subdivisions and Survey for Engineers and Surveyors, 2022 California Green Building Standards Code (CalGreen), Land use limitations County zoning ordinances, contact Planning Division, Geologic hazards Landslides, geotechnical (soils) report. Contact Us Call or Text: (888) 763-7663 Email: info@wedgeroofing.com Construction Services Dry Rot and Structural Repairs Decks Siding Installation and Repair Most jurisdictions follow the International Building Code, which devotes one sectionR507to deck construction. 10.10 Spacing of braced wall lines shall not exceed 25 feet (interior & exterior) unless length of required bracing, per Table R602.10.3(3) is adjusted in accordance with Table R602.10.3(4). Chapter 7 of the Sonoma County Code is hereby amended as follows: (a) Section 7-3, Local appeals board and housing appeals board is revised to read: Sec. 10.9 Braced wall lines shall be sized and configured in accordance with section R602.10 in its entirety. To ensure your design meets code, confer with the Authority Having Jurisdiction (AHJ) over your project. I also always place steel bars vertically and horizontally in the concrete for added strength. What you will notice from this checklist is that there is not really a specific deck building code per se. Reviews construction plans prior to issuance of a building permit to ensure the project will conform to the uniform construction codes (building, electrical, plumbing, and mechanical) and sound engineering practices. Attachment methods vary depending on the style of stairs but this is a very common and reliable technique. 11.2 Rafters shall be sized and framed in accordance with CRC Section R802.4, and the referenced span tables. So build your deck the right way, from the ground and posts up. Solar Permits for Residential Rooftop Systems. We are also located near the ocean and with that a higher content of corrosive salt. Transportation and Public Works is now Sonoma Public Infrastructure - Website updates coming soon! It's usually pretty easy to recognize. Material: HOW TO PICK THE RIGHT MATERIAL? (R302.11), 3.6 There shall be a floor or landing at the top and bottom of each stairway. (R802.8) Nail blocking to top plate with (3) 8d toe nails per block or provide clips. Who Performs Inspections? (R408.4; CPC 707.9), 7.14 Fire blocking shall be provided in concealed spaces of stud walls and partitions, including furred spaces, and parallel rows of studs or staggered studs; vertically at floor and ceiling levels, horizontally at intervals not to exceed 10 feet. You may Omission of any items in the following list may result in delay of plan check, requiring resubmission of documents or information. (R406 & R703), 4.4 Concrete slabs shall be separated from earth by a minimum 6 mil vapor retarder, with edges lapped a minimum of 6 inches. 2004-2022 Decksgo.com. This may be omitted if the space above is not heated and is not likely to become heated in the future. Call (707) 784-6765. Spans shall be per Tables R802.4(1) & (2) for ceiling joists and Tables R802.5.1(1) & (2) for rafters. Provide adequate drainage information, e.g. officials know their territories so give them a call or check on-line. (CPC 402.5). 4.1 Naturally durable wood or preservative treated wood, per AWPA U1, shall be required in the following locations (R317.1): 4.2 Exposed glulams shall be preservative treated, applied by the manufacturer, or made from naturally durable wood. (CMC 305.1). 2.6 Attic ventilation: 1/150 of attic area. There are numerous building departments in California. (R 403.1.6) Provide minimum 3 inch by 3 inch by 0.229 inch plate washers on each bolt. The 30" Rule As a general rule, you need a permit for any deck that is higher than 30 inches off the ground. Cripple walls shall be sheathed per R602.10.9 & R602.10.9.1. Carbon monoxide alarms are not required in dwellings where there is no fuel-fired appliance or attached garage. Garage to dwelling unit separation is not a rated firewall. 17-9 Wood Deck Construction 17-9 Glass and Glazing. 2022 Model Building Codes Local Workshop News. When in doubt: Common sense just tells you to use 1500 LB/sq.ft. (R317.3.1). Newly constructed residential dwelling units, including accessory dwelling units (ADUs), shall be designed and constructed as all-electric dwellings. A 36 rail measured from the top of rail to the deck surface is required. ADMINISTRATION Chapter 3. Building codes must still be followed and other permits might still apply (e.g. (CalGreen 301.1.1). For foundation requirements for light frames walls with brick veneer, see Table R403.1(2). Input your elevation change and this will figure out your rises and runs, Maximum 36 "oc solid stringer spacing for 2" thick treads, Maximum 18 "oc notched stringer spacing for 2" or 5/4 "thick treads, Maximum nosing of 0.75 "to 1.25" - maximum nosing radius of 9/16 ", Closed risers: minimal nominal 1" thick riser material, Handrails must not project inwards more than 4.5" on either side of stairway. Run shall be 10 inches minimum. Wall assemblies shall extend from the foundation to the underside of the roof sheathing, although wall assemblies need not extend through attic spaces where the ceiling is protected by not less than 5/8 inch Type X gypsum board, an attic draft stop is provided above and along the wall assembly separating the dwellings, and the structural framing supporting the ceiling is protected by not less than inch gypsum board or equivalent. Limitations on deck materials and construction 5. As used in this chapter unless a different meaning clearly appears from the context: (1) "Building" means a structure having a roof and intended to shelter persons, animals, property or a business activity. Provide protective bollard or other impact barrier or located out of the normal path for vehicles. Gridlines shall be provided corresponding to the lateral load resisting gridlines identified as required in Section 1.7 below. The City charges for building permits to cover the cost of plan review and inspections. Tables for the minimum joist spansin California's moderate climate regions, How we build a closed in riser stair for decks with a skirt for solid railings, Deck stair total rise table with calculations for riser heights and number of treads, Alter Eagle Building Permits. 812 - Rural County Road, Driveway and Private Road Intersections 815 - Rural Driveway / Roadway 816 - Rural Driveway Drainage, Ditches 818 - Rural Driveway Drainage, Valley Gutters 820 - Rural Driveway Drainage, Culverts Design 900A - Rural Typical Road Cross-Sections 900B - Urban Typical Road Cross-Sections Dimension front, side and rear distances to property lines and between structures. Building Permit with Plan Check to Permit IssuanceView how long it took from application submission, to first review comments, to permit issuance during the previous month. 12.1 New construction and additions/alterations increasing a buildings conditioned floor area or volume shall comply with applicable provisions of CalGreen. Certain projects receive expedited permit processing. Welive in the beautiful wine country of Northern California, it just doesn't get much better than this. Headroom shall be 80 inches minimum. Chapter 7, Article IIof Sonoma County's Municipal Code outlines Building Regulations for the unincorporated area of this county. We've tried to summarize them and put them all together for you. 1.6 Framing Plans: Identify framing members and sheathing for floor and roof & ceiling plans. 3.8 Exterior deck support posts shall be cross-braced in two directions for lateral stability. learn more about building decks from builders and people like you. A lockable means of disconnect must be installed, per applicable PG&E requirements. 36 "minimum height when surface is 30" + above grade, 50 lb concentrated load over 1 sqft or balusters, 50 lbf vertical and horizontal load along top rail, 4 "maximum gap between deck and underside of bottom rail, 34 "minimum stair rail height from nosing to top of rail. 1.7 Wall Bracing Plans/Shear Wall Plans: Provide plans which adequately dimension all braced wall segments and locations for non-engineered plans, and/or identify and dimension engineered shear wall locations and minimum lengths. Table R602.3(1). Article II. This document provides building code information applicable to prescriptive residential wood deck design. 2035) Chapter 7. The IRC deck joist span table Serving North Marin & West Sonoma Counties in the San Francisco North Bay area of Northern California 2 grade lumber. Click for a larger images Learn how to trace the number and size of rises and runs to cut out your stair stringer. Guards are required when then deck is 24 "(60 cm) above grade. The deck we build in this article is approximately 20 inches off the ground and as a result is not required by code to have a railing system on the steps or deck. You need a permit to build a deck if it is: More than 18 inches above the ground A roof deck (built on top of part of the building) In an environmentally critical area (ECA), for example landslide-prone areas. Sandy gravel, gravel: Gravel and sand will settle in water almost immediately. (Table R602.3) Nailing shall be inspected prior to covering. Wood columns shall not be less in nominal size than 4" x 4" IBC 2304.9.7 Column and post-end connections shall be fastened to resist lateral and net induced uplift forces. Envision a town with the best qualities of turn-of-the century America, yet with the ambiance of a European countryside. An added beam allows independent movement of the deck, natural expansion and contraction and no possibility of trapped moisture damaging your home over the many years our decks last. (CMC80230). We also add a stringer to the center and each step is within 1/16 to 1/8 of an inch. (R314.2.2), 6.11 For new construction and work in an existing dwelling, where an addition is made to an existing dwelling or a fuel-burning appliance is added, carbon monoxide alarms shall be installed in sleeping rooms within which fuel- burning appliances are installed, outside of each sleeping area, and on each occupiable level. Building Code, Zoning Ordinances, and all other relevant laws, ordinances, rules and regulations. Rules and Regulations. Procedures Handout for As Built Projects (PDF) Inspectors Area Description (PDF) The glazed area need not be openable for ventilation when a whole house ventilation system is installed (R303.1). The new code requires railings to be 42 inches high. Provide curtain rod or approved enclosure material. 2022 County of Sonoma. Where county road encroachment is necessary, a permit for same shall be first secured. The stairway shall have landings at each floor, or level, of not less than 30 inches in the direction of travel and extend at least 24 inches in width at every Find out exactly how many balusters or pickets you need with a single click. (R403.1.5), 8.6 Concrete slabs shall be 3.5 inches thick minimum. (R703.3.3), 4.8 Corrosion resistant flashing shall be provided at openings and intersections/attachments. (CMC 903.2.3). (R307.2). Make sure your project does not extend into those areas. (CMC 802.0), 2.4 Each bathroom containing a bathing facility shall be mechanically ventilated for the purposes of humidity control. If the proposed scope of work does not result in the removal of wall and ceiling, finishes exposing areas requiring installation devices may be battery operated. Always refer to your local building codes or a structural engineer this is how we build our decks, Deckfooting & piersizing for California, Deck connections for California's #4 earthquake zone. (R311.3), 3.3 Stairway rise shall be 4 inches minimum and 7 inches maximum. Required guards shall be not less than 42 inches above the adjacent walking surface, except that handrails may be considered as guards at stairways. diameter or square x thickness - 1,500 psf bearing, TABLE R401.4.1 - PRESUMPTIVE LOAD-BEARING VALUES OF FOUNDATION MATERIALS, Sand, silty sand, clayey sand, silty gravel and clayey gravel, Clay, sandy clay, silty clay, clayey silt, silt and sandy silt. dwelling area, garage area, covered porches, decks, retained square footage retained at the face of retaining walls, storage areas, basements, etc.). Get Quotes and Book Instantly. You can use your mousewheel to scroll though all of the pictures, Serving North Marin & West Sonoma Countiesin theSan Francisco North Bay area of Northern California, Footings recommended by the 2010deck prescriptive. "Building Official" means the Chief Building Official as defined in Section 7-2 of the Sonoma County 18.10 Glass and Glazing. Provide North Arrow and drawing scale. And they are the hardest and most labor intensive part of building a deck. When we design decks for our area there are specific building practices we follow to keep you safe. Be sure to find out - You don't want any surprises after its built. 11.6 Wood structural panel sheathing, when designed to be permanently exposed in outdoor applications, shall be of an exterior exposure durability. Did you know there are at least nineteen different possible ways of securing posts into the framing. I have a large deck. 10.7 Minimum wood structural panel sheathing nailing: 6 inches on center at edges and 12 inches on center in field. Wood siding, sheathing and wall framing on the exterior of the building having a clearance of less than 6 inches from the ground or less than 2 inches from a horizontal concrete surface. IRC R319.1 & IBC 2304.11 (California Energy Code Section 100(b)). Decks building codes - Footings - IRC & IBC IRC R403 & IBC 1805 Footings Footings shall be supported on undisturbed natural soils or engineered fill. 55 11 99270-9895 [email . All rights reserved. The footing bottoms are located a minimum of 12 inches below undisturbed groundat native soil or below the frostline whichever is the deepest. Inspections will be performed on any external building element six feet above ground level including walkways, balconies, decks, landings, stairways and railings. Building permits for projects regulated by the California Fire Code and Sonoma County fire safe standards may be subject to review and approval by appropriate fire service agencies. Thirty-six inches is the most common residential height, but some jurisdictions vary. According to the California Building Standards Code, no building or structure may be erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted, or demolished unless a separate .